NI RFmx LTE/LTE Advanced/LTE-V2X/NB-IoT/eMTC 2023 Q4 Win11 64bitEng RFmx LTE演进蜂窝测试软件23.8
NI RFmx LTE/LTE Advanced/LTE-V2X/NB-IoT/eMTC 2023 Q4 Win11 64bitEng RFmx LTE演进蜂窝测试软件23.8RFmx LTE/LTE-Advanced
RFmx LTE/LTE-Advanced为LTE、LTE-Advanced和LTE-Advanced Pro蜂窝测试应用提供信号生成和分析功能。
RFmx LTE/LTE-Advanced是一个测量API,旨在扩展NI RF仪器生成和分析LTE、LTE-Advanced和LTE-Advanced Pro蜂窝信号的能力。该软件可以通过误差矢量幅度(EVM)、相邻信道泄漏比(ACLR)、频谱发射屏蔽(SEM)等符合标准的物理层测量,对FDD、TDD和LAA信号进行分析。借助RFmx,您可通过交互式软面板快速轻松地执行和调试测量,使用RFmx Waveform Creator创建和回放开放的未锁定波形,并结合更高性能的API加快自动化测试的速度。
RFmx LTE同时包含了NI RFmx LTE-V2X和NI RFmx NB-IoT/eMTC驱动程序。
RFmx LTE-V2X
RFmx LTE-V2X为LTE-V2X蜂窝测试应用提供信号生成和分析功能。
RFmx LTE-V2X是RFmx LTE/LTE-Advanced测量API的驱动程序,旨在扩展NI RF仪器生成和分析基于LTE的蜂窝V2X (C-V2X)信号的能力。该软件可以通过误差矢量幅度(EVM)、相邻信道泄漏比(ACLR)、频谱发射屏蔽(SEM)等符合标准的物理层测量,对 LTE辅链路PC5信号进行分析。借助RFmx,您可通过交互式软面板快速轻松地执行和调试测量,使用RFmx Waveform Creator创建和回放开放的未锁定波形,并结合更高性能的API加快自动化测试的速度。该软件随RFmx LTE/LTE-Advanced一起安装。
RFmx NB-IoT/eMTC
RFmx NB-IoT/eMTC为NB-IoT和eMTC蜂窝测试应用提供信号生成和分析功能。
RFmx NB-IoT/eMTC是RFmx LTE/LTE-Advanced测量API的驱动程序,旨在扩展NI RF仪器生成和分析NB-IoT和eMTC蜂窝信号的能力。该软件可以通过误差矢量幅度(EVM)、相邻信道泄漏比(ACLR)、频谱发射屏蔽(SEM)等符合标准的物理层测量,对LTE Cat-NB1/NB2和LTE Cat-M1/M2上行链路信号进行分析。借助RFmx,您可通过交互式软面板快速轻松地执行和调试测量,使用RFmx Waveform Creator创建和回放开放的未锁定波形,并结合更高性能的API加快自动化测试的速度。该软件随RFmx LTE/LTE-Advanced一起安装。
Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://visionbbs.com/thread-490-1-1.html
视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://visionbbs.com/thread-26524-1-1.html
NI RFmx LTE/LTE Advanced/LTE-V2X/NB-IoT/eMTC 2023 Q4
发布日期:2023/10/11
包含的版本:2023 Q4完整版/运行版,版本号23.8.0
受支持的操作系统:
Windows 11
Windows Server 2022 64-bit
Windows 10 64-bit
Windows Server 2016 64-bit
Windows Server 2019 64-bit
语言:English
应用程序位数:64位
64位完整版校验和:
文件大小: 1431017472 字节 (1.33 GB)
修改日期: 2023-10-12 09:45
MD5: e706e2d284aa71590b9500358e08b515
SHA1: 9ed802b420f7f4efbc37cb9f0f61d2fa47ee2c4e
SHA256: 3edeffbc7391a3faca2d01e2a5aae961964e75fc8ba42ff15942a30eba3d50bf
CRC32: a0726398
百度网盘和NI官方下载地址:
请注册登录机器视觉论坛账号,购买附件查看下载地址
64位运行版校验和:
文件大小: 693288960 字节 (661.17 MB)
修改日期: 2023-10-12 09:45
MD5: e7c348ce771e5a59cc6f97bfee73ae06
SHA1: 777f0e7610bea24b74452e678f442a7f112ce984
SHA256: 365e63b7a64ba55b7206bb254211eea3ca793f3bb6470e5c5c7c9ba466e11738
CRC32: 955a8294
百度网盘和NI官方下载地址:
请注册登录机器视觉论坛账号,购买附件查看下载地址
2023Q4版未更新自述文件,参考2023Q3版
RFmx LTE 2023 Q3 ReadmeJuly 2023This file contains important information about the RFmx LTE, including system requirements, and installation instructions.You can find more release information on ni.com.
[*]RFmx LTE-V2X Release Notes: Known issues, bugs fixed since the last release, and other notes about this release
[*]RFmx LTE/LTE-Advanced Release Notes: Known issues, bugs fixed since the last release, and other notes about this release
[*]RFmx LTE-V2X Manuals: New features, behavior changes, and other documentation
[*]RFmx LTE/LTE-Advanced Manuals: New features, behavior changes, and other documentation
New FeaturesSupported HardwareSystem RequirementsSupported Operating SystemsApplication Software SupportInstallation InstructionsInstalled SoftwareFile LocationsExecutableAccessing the APIAccessing the DocumentationFinding ExamplesProduct Security and Critical UpdatesBehavior ChangesAutomating the Installation of NI ProductsUsing NI Software with Microsoft Windows 11New FeaturesRFmx LTE 2023 Q3 includes the following new features:
[*]Support for Noise Compensation in ACP measurement for Sequential FFT mode
RFmx LTE 2023 Q2 includes the following new features:
[*]Support for configuration of Phase and Time tracking modes in ModAcc measurement
[*]Speed improvements for Composite and Spectral measurements
RFmx LTE 2023 Q1 includes the following new feature:
[*]Support for LabVIEW 2023 Q1 (64-bit)
[*]Support for NS_28, CA_NS_09, and CA_NS_10 masks in the SEM Measurement
Supported HardwareVisit NI Hardware and Software Operating System Compatibility to view driver, desktop operating system, and real-time operating system support for individual hardware devices.To view information for your device:
[*]Select your hardware model in the dropdown list on the page to view compatibility information for your device.
[*]Type your hardware model number in the dropdown list on the web page to filter the list of available devices.
Note: Some compatibility information may only be available in the archive attached to the NI Hardware and Operating System Compatibility page. For historic driver and OS support information, refer to the readme for the relevant driver version.System RequirementsRFmx LTE has the following requirements:
[*]Processor—1 GHz 64-bit (x64) processor
[*]4 GB RAM *
[*]A screen resolution of 1,024 x 768
[*]Any supported OS, with all available critical updates and service packs
* Depending on the amount of data acquired and/or processed, a larger amount of memory may be required.Supported Operating SystemsRFmx LTE 2023 Q3 supports the following 64-bit operating systems:
[*]Windows 11
[*]Windows 10
[*]Windows Server 2022
[*]Windows Server 2019
[*]Windows Server 2016
Application Software SupportRFmx LTE supports the following application software versions, including service packs. You should install application software, such as LabVIEW or Microsoft Visual Studio®, before installing RFmx LTE. If you are not using NI application software, refer to Microsoft Visual Studio Support.
Application SoftwareVersions Supported by RFmx LTE (64-bit only)
LabVIEW2020 SP1, 2021 SP1 f1 patch, 2022 Q3, 2023 Q1, 2023 Q3
Required Software
[*]NI-RFSA 14.1 or later
[*]NI-RFSA 17.1 or later (for initializing debug session when "using breakpoints in C/C++/.NET application" is selected)
Microsoft Visual Studio SupportIf you are using the RFmx LTE .NET Class Library, .NET Framework 4.0 (minimum) is required. The RFmx LTE .NET Class Library can be used with Visual C# or Visual Basic .NET in any Visual Studio version that can target .NET Framework 4.0 or .NET Framework 4.5.Installation InstructionsDownload the RFmx LTE installer from ni.com/downloads. NI software includes NI Package Manager to handle the installation. Refer to the NI Package Manager Manual for more information about installing, removing, and upgrading NI software using NI Package Manager.Notes
[*]If you purchased this product with an NI Software Suite or NI Product Bundle, use the installation media that shipped with your purchase to install this product.
[*]RFmx LTE installs the following licensed products
[*]LTE: This will enable analysis of FDD and TDD signals with standard-compliant physical layer measurements such as Error Vector Magnitude (EVM), Adjacent Channel Leakage Ratio (ACLR), Spectrum Emission Mask (SEM), Channel Power (CHP), Occupied Bandwidth (OBW), Power Versus Time (PVT), SlotPhase, and SlotPower measurements.
[*]LTE-Advanced: This will enable analysis of LTE Advanced and LTE Advanced Pro features such as Carrier Aggregation, Higher Modulation Schemes, License Assisted Access (LAA) with standard-compliant physical layer measurements such as Error Vector Magnitude (EVM), Adjacent Channel Leakage Ratio (ACLR), Spectrum Emission Mask (SEM), and more
[*]NB-IoT/eMTC: This will enable analysis of LTE Cat-NB1/NB2 and LTE Cat-M1/M2 Uplink signals with standard-compliant physical layer measurements such as Modulation Accuracy (ModAcc), Adjacent Channel Leakage Ratio (ACLR), Spectrum Emission Mask (SEM), and more.
[*]LTE-V2X: This will enable analysis of sidelink PC5 signals with standard-compliant physical layer measurements such as Modulation Accuracy (ModAcc), Adjacent Channel Leakage Ratio (ACLR), Spectrum Emission Mask (SEM), and more.
NotesIf Windows Update is enabled, the installation process might hang if Windows Update interferes with the installation of Microsoft Visual C++ 2015 Run-Time. Visit ni.com/r/exjq43 for more information and steps to resolve this issue.Use the serial number that is included with your software to activate the product. Refer to the NI Software Activation for more information on product activation.Installed Software
[*]<MSTUDIOVS2010DIR> is an alias for the following National Instruments file folder location:
[*]Program Files (x86)\National Instruments\MeasurementStudioVS2010
[*]<NIDir> is an alias for the following National Instruments file folder location:
[*]Program Files (x86)\National Instruments
[*]<SYSDIR> is an alias for the following file folder location:
[*]Windows\SysWOW64 for 32-bit programs and windows\system32 for 64-bit programs
File Locations
ItemInstalled Location
Version Compatibility Checker<NIDir>\RFmx\niRFmxCompatibility_Checker.exe
Debug Configuration Utility<NIDir>\RFmx\niRFmxDebugConfigurationUtility.exe
DLLs<SYSDIR>
Header files<NIDir>\Shared\ExternalCompilerSupport\C\include
Import Library files
[*]32-bit: <NIDir>\Shared\ExternalCompilerSupport\C\lib32\msvc
[*]64-bit: <NIDir>\Shared\ExternalCompilerSupport\C\lib64\msvc
.NET Class Libraries
Assemblies<MSTUDIOVS2010DIR>\DotNET\Assemblies\Current\NationalInstruments.RFmx.LteMX.Fx40.dll
<MSTUDIOVS2010DIR>\DotNET\Assemblies\Current\NationalInstruments.RFmx.InstrMX.Fx40.dll
<MSTUDIOVS2010DIR>\DotNET\Assemblies\Current\NationalInstruments.Common.dll
ExecutableSelect Start » National Instruments » InstrumentStudio to launch the InstrumentStudio.Accessing the APIRFmx LTE palette VIs are available from the Functions » Measurement I/O » RFmx » LTE palette.Accessing the DocumentationDocumentation for RFmx LTE is located at Start » National Instruments » RFmx LTE Documentation.Finding ExamplesYou can access all the installed RFmx LTE examples at Start » National Instruments » RFmx LTE Examples.For the most recent revisions of documentation and for newly released documentation, visit ni.com/manuals.Product Security and Critical UpdatesVisit ni.com/security to view and subscribe to receive security notifications about NI products. For information about critical updates from NI, refer to Available Critical and Security Updates for NI Software.Behavior ChangesThe following is the behavior change in RFmx LTE 2023 Q3 from RFmx LTE 2023 Q2
[*]Added support for saving and loading RFmx configurations into/from rfmxconfig files. Load from TDMS is supported but save into TDMS files is discontinued.
The following items are the behavior changes in RFmx LTE 2022 Q4 from RFmx LTE 2022 Q3
[*]RFmx LTE drops support for 32-bit user mode.
The following items are the behavior changes in RFmx LTE 2022 Q3 from RFmx LTE 21.8.2
[*]The RFmx Soft Front Panel has been replaced by InstrumentStudio.
The following items are the behavior changes in RFmx LTE 21.8 from RFmx LTE 21.5
[*]Obsoleted Subblock Freq Definition property. Use Subblock Freq (Hz) property for configuring subblock frequency offset from the center frequency.
Automating the Installation of NI ProductsYou can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes.If the NI product you are installing uses Microsoft .NET 4.6.2, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.6.2 separately before you install NI software.For more information about automating the installation of NI products, refer to Automating an Installer in the NI Package Manager manual.Using NI Software with Microsoft Windows 11Microsoft Windows 11 is the latest version of the Windows operating system and features significant changes compared to previous versions. For more information about NI support for Windows 11, refer to NI Product Compatibility for Microsoft Windows 11.
页: