宝视纳Basler-blaze pylon补充软件包 1.6.0 - Linux ARM 64位~pylon-supplementary-package-for-blaze-1.6.0.b542964d0_aarch64_setup.tar.gz
宝视纳Basler-blaze pylon补充软件包 1.6.0 - Linux ARM 64位~pylon-supplementary-package-for-blaze-1.6.0.b542964d0_aarch64_setup.tar.gzpylon Supplementary Package for ToF Camera / blaze 1.6.0
2023年9月
1.6.0
Compatible with: pylon 6.2.0, 6.3.0, 7.0.0, 7.2.1, 7.3.0, 7.4.0
在此处下载blaze pylon补充软件包,轻松设置和配置Basler blaze 3D相机。这个软件包包含blaze Viewer,以作为配置和可视化工具。
安装要求
blaze pylon补充软件包需要安装pylon相机软件套装6.2.0或更高版本。
blaze pylon补充软件包 1.6.0 - Linux ARM 64位
文件名: pylon-supplementary-package-for-blaze-1.6.0.b542964d0_aarch64_setup.tar.gz
文件大小: 80809806 字节 (77.07 MB)
修改日期: 2024-10-24 17:52
MD5: 1fbe9cf6e3edfa45c356a634f4d2ff3b
SHA1: 754769f881ade83d400cb9ff5f4d3ac52533d79e
SHA256: e47738a3342687fb54d5dec3b4d0ecb38726738e0c69e26ff1159fe780c204df
CRC32: d407b7f2
Basler官方下载:
**** Hidden Message *****
百度网盘下载:
链接:https://pan.baidu.com/s/1IDttWbp3mGGpoLZy7_v50g
提取码:**** Hidden Message *****
RELEASE NOTES
==============
pylon Supplementary Package for blaze
Version: 1.6.0
Release date: 2024-05-03
Preceding release: 1.5.0
Products affected: blaze-101 (order number 107796), revisions 03 or above
blaze-102 (order number 108711)
NEW FEATURES
------------
* Improved handling of the GigE Vision heartbeat timeout. In case an application
has been started under the control of a debugger, the connection to the camera
is closed automatically when the application is terminated or crashes. This
allows you to use the GigE camera again immediately after restarting the
application. pylon 7.1 or above is required for the improved heartbeat timeout
becoming effective.
CHANGES
--------
* Updated OpenCV and Point Cloud Library installation topics in the blaze
C++ Programmer's Guide.
* Fixed an issue causing the producer to not acquire images when the Extended ID
feature is enabled (under Windows with pylon GigE Vision Performance Driver).
Note that the pylon GigE Vision Performance Driver has been discontinued.
You should use the pylon GigE Vision Filter Driver instead.
* Fixed an issue causing the blaze Viewer to crash when the content of the
feature tree search box was deleted.
* Fixed an issue causing the frame ID to only go up to 65535 when the Extended ID
feature was enabled and then to overflow (under Windows with pylon GigE Vision
Filter Driver).
* Fixed an issue where the Gamma Correction feature didn't work properly when
using camera firmware version 4.x.
* Fixed the return type of GetBufferPartInfo BUFFER_PART_INFO_DATA_TYPE
from int to size_t.
* Added the AutoPacketSize and UseExtendedIdWhenSupported parameters. Usage of
GigE Vision Extended IDs is enabled by default.
KNOWN LIMITATIONS
------------------
Windows, pylon versions below pylon 7.2.1:
- Basler generally recommends using pylon 7.3 or above with blaze cameras.
Linux:
- Programming samples using the Point Cloud Library (PCL) may crash depending
on the versions of the PCL and VTK libraries installed on your system. The
crash is due to a bug in the VTK libraries that are used by PCL for 3D
visualization.
Source: https://github.com/PointCloudLibrary/pcl/issues/5237
For example, Ubuntu 22.04 ships versions of the libraries showing the problem.
Solution: PCL 1.13.1 and above contain fixes to work around the VTK bug.
Uninstall the PCL libraries provided by your Linux distribution and build PCL
version 1.13.1 or above from sources (these are available on
https://github.com/PointCloudLibrary/pcl).
页: